Fire Extinguisher AMC & Refilling Services - Ahmedabad, Gujarat & Across India
Fire Systems Pvt. Ltd. is a leading safety and compliance partner in India. We offer certified fire extinguisher refilling, annual maintenance contracts (AMC), gas filling, pressure testing, and service register maintenance in strict compliance with IS 2190 standards for commercial offices, industrial plants, residential complexes, and public institutions.
Why Fire Extinguisher Maintenance Is a Legal Requirement
A fire extinguisher that is empty, discharged, or past its service date is legally equivalent to having no fire extinguisher at all - and may result in non-renewal of your fire NOC. Under Rule 54 of the Gujarat Fire Prevention and Life Safety Measures Act and the provisions of the Factories Act, all fire extinguishers on premises must be maintained in serviceable condition, tested, and recorded in a service register.


Types of Fire Extinguishers We Service
We deploy certified refilling, maintenance, and testing services for all major types of fire extinguishers in compliance with safety standards.
| Type | Agent | Fire Classes | Common Applications |
|---|---|---|---|
| ABC Dry Powder | Monoammonium phosphate powder | A, B, C | General purpose - factories, offices, vehicles |
| CO₂ (Carbon Dioxide) | CO₂ gas | B, C | Electrical equipment, server rooms, laboratories |
| Wet Chemical | Potassium acetate solution | A, F | Commercial kitchens, cooking oil fires |
| Water | Water (pressurised) | A | General - paper, wood, fabric fires |
| AFFF Foam | Aqueous Film Forming Foam | A, B | Flammable liquid storage, vehicle fires |
| Clean Agent (HFC) | HFC-236fa or similar | A, B, C | Electronic equipment, museums |
| Mechanical Foam | AFFF or FFFP solution | A, B | Industrial, aviation, flammable liquid stores |
What Our AMC Covers
Regular maintenance is crucial to ensure that your fire extinguishers function perfectly during an emergency. Under IS 2190 standards, we cover all aspects of inspection, refilling, pressure testing, and certification.
Annual Inspection Visual check of cylinder body, hose, nozzle, pressure gauge, and safety pin.
Refilling & Recharging Refill with correct agent type and quantity per manufacturer and IS specifications.
Hydrostatic Testing Mandatory testing every 3–5 years (per IS 15683) to verify cylinder shell integrity under hydraulic pressure.
Service Label & Record Affix service date, technician name, and next service date on each cylinder, and maintain the register.
Replacement Supply Worn-out or condemned cylinders replaced promptly with certified new ones.
Placement Audit Verification that extinguisher type, quantity, coverage, and placement meet IS 2190 occupancy norms.
Staff Demonstration Brief demonstration of correct extinguisher use (PASS method) for designated first-responders.
IS Codes & Standards for Fire Extinguishers
Every fire safety selection, installation, and refilling service is performed in strict compliance with the Bureau of Indian Standards (BIS) codes and national regulatory guidelines to guarantee optimal performance and hassle-free Fire NOC renewals.
IS 2190
Code of Practice for Selection, Installation, and Maintenance of First Aid Fire Fighting Equipment.
IS 15683
Governs portable fire extinguishers' performance, construction, and safety testing guidelines.
IS 13386
Detailed specifications, testing procedures, and compliance rules for Carbon Dioxide (CO₂) extinguishers.
IS 10658
Detailed chemical testing and construction requirements for ABC dry powder extinguishers.
NBC 2016 Part 4
National Building Code regulations governing extinguisher types, quantities, and placement across occupancies.
How Many Fire Extinguishers Do You Need?
Selecting the correct quantity and capacity of fire extinguishers depends on the risk class and total floor area, as outlined under IS 2190 regulations:
| Building Type | IS 2190 Requirement |
|---|---|
| General occupancy (low risk) | 1 x 9-litre water or ABC per 200 sq.m. floor area |
| General occupancy (moderate risk) | 1 x 9-litre water or ABC per 100 sq.m. floor area |
| Industrial / high risk | Based on specific fire risk assessment |
| Commercial kitchen | Minimum 1 x wet chemical in kitchen; 1 x CO₂ for cooking equipment |
| Server room / electrical |
CO₂ or Clean Agent Only Water and powder prohibited to protect sensitive electronic infrastructure. |
Frequently Asked Questions - Fire Extinguisher AMC
Find answers to common questions about fire extinguisher AMC services, refilling, hydrostatic testing, and GIDC coverage:
IS 2190 and most fire authority requirements specify annual inspection and servicing of all fire extinguishers. Hydrostatic pressure testing is required every 3 years for most types and every 5 years for CO₂ extinguishers. Service records must be maintained on-site.
Hydrostatic testing involves filling the extinguisher cylinder with water and pressurising it to 1.5× working pressure to check for leaks, cracks, or deformation in the cylinder shell. This test is required periodically to ensure the cylinder remains structurally safe under the pressures of normal use and refilling. Cylinders that fail hydrostatic testing must be condemned and replaced.
Yes. CO₂ extinguishers are specifically recommended for electrical equipment fires - they do not leave residue (unlike dry powder) and are non-conductive. They are the preferred type for server rooms, switch rooms, and electrical panels. Do not use water or foam extinguishers on live electrical equipment.
A fire extinguisher needs refilling if the pressure gauge reads in the red zone, if the safety pin has been removed and replaced (suggesting partial discharge), if the last service date is more than 12 months ago, or if any physical damage (dents, corrosion, blocked nozzle) is observed. When in doubt, have it serviced - a partially discharged extinguisher may fail to extinguish a real fire.
Yes. We provide fire extinguisher AMC services across Ahmedabad's industrial areas including GIDC Vatva, Naroda, Odhav, Changodar, and surrounding industrial estates. We manage scheduled servicing for multiple factories under a single AMC contract.
Ensure Legal Compliance & Safety for Your Building
We serve Ahmedabad, Surat, Vadodara, Rajkot, Gandhinagar, and all of Gujarat. Contact us today for a free fire safety audit, extinguisher layout inspection, and annual maintenance contract quote.
Request a Site Survey
Schedule a visit from our certified safety engineers for a customized fire extinguisher survey and AMC quotation.