CF-30004G 4 LOOP ADDRESSABLE FIRE ALARM CONTROL PANEL

Eaton’s CF3000 is a high specification intelligent addressable control panel which is available in various loop configurations. These panels combine sophisticated functionality with simple operation and an aesthetically pleasing design.

The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments.

The CF3000 uses soft addressing to minimize installation time and remove the potential for error associated with manual addressing. It can operate as a stand alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local.

An extensive range of compatible intelligent addressable systems ancillaries are available to work with the CF3000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.

Product Description

• Available in 4 loop version
• Up to 200 addresses per loop
• Full network capability up to 126 panels
• Event History Buffer (9,999 events) with Date/Time stamp
• Soft addressing
• Large versatile touch screen user interface
• Multi-language selection capability
• Integral printer (optional)
• Integral battery and power supply
• Flexible cause and effect programming
• Simple to operate end user touch-screen interface
• Flexible distributed network capability
• Full range of compatible accessories
• Easy to design system cause and effect using site installer software
• Full system integrity with Eaton’s managed protocol

Code CF30004G
Description 4 loop control panel
Standards EN54 Pt2,1997, A1:2006, EN54 Pt4,1997, A1:2002, A2:2006 EN54 Pt13: 2005 EN54 Pt2,1997, A1:2006, EN54 Pt4,1997,
A1:2002, A2:2006 EN54 Pt13: 2005 EN54 Pt2,1997, A1:2006, EN54 Pt4,1997, A1:2002, A2:2006 EN54 Pt13: 2005 Specification
Number of loops 1 2 4 Addresses per loop 200 200 200
Number of conventional sounder circuits 4 monitored for open and short circuit 4 monitored for open and short circuit 4 monitored for open and short circuit
Auxiliary fire routing equipment output (monitored)
24V 30mA (max) 24V 30mA (max) 24V 30mA (max)
Auxiliary fire protection equipment output (monitored)
24V 30mA (max) 24V 30mA (max) 24V 30mA (max)
Auxiliary fault routing equipment output (monitored)
12V 30mA (max) 12V 30mA (max) 12V 30mA (max)
System operating voltage 24V dc (nom) 24V dc (nom) 24V dc (nom)
Mains input supply 230V ac +10% / -15% 230V ac +10% / -15% 230V ac +10% / -15%
Class change facility Terminals for connection of external contacts, can also be instigated via input interface
Terminals for connection of external contacts, can also be instigated via input interface
Terminals for connection of external contacts, can also be instigated via input interface
Auxiliary relay 1 set of changeover contacts operate in event of fire condition
1 set of changeover contacts operate in event of fire condition
1 set of changeover contacts operate in event of fire condition
Output ports RS485, RS232 for connection of repeaters etc
RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc
Standby duration Dependant on loop loading and battery configuration
Dependant on loop loading and battery configuration
Dependant on loop loading and battery configuration
Battery 2 x 12Ah (standard versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions)
2 x 12Ah (standard versions) 4 x 12Ah (EB versions)
Environmental Operating temperature -5°C to +40°C -5°C to +40°C -5°C to +40°C Humidity (non condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH
Physical Construction Back box – mild steel, front door – PC/ABS Back box – mild steel, front door – PC/ABS Back box – mild steel, front door – PC/ABS
Dimensions (H x W x D) Standard versions: 397mm x 497mm x180mm
Standard versions: 397mm x 497mm x 180mm EB Versions: 397mm x 497mm x 280mm
Weight 18kg
Ingress protection IP30
Cable entries Top: 31 cable knockouts (20mm) Back: 12
cable knockouts (20mm)
Top: 31 cable knockouts (20mm) Back: 12
System networking Fully networkable up to 126 panels
(requires additional network card – 1 per panel)
Fully networkable up to 126 panels
(requires additional network card – 1 per panel)
Fully networkable up to 126 panels(requires additional network card – 1 per panel