Morley Lite Semi Addressable Fire Alarm Panel

Honeywell Morley Lite is a Compact, High Performance, Feature enriched Fire Alarm Control Panel designed to meet the Fire Detection Addressability. Honeywell Morley-Lite Fire Detection Control Panel series is ideally suited for Small to Medium Sized Buildings, Residential Complexes, Banks, Healthcare, Restaurants, Retail Stores etc. Morley Lite panels communicates via LiteSpeedTM protocol with Morley Lite detectors and devices.

Morley Lite Panel is built with Combination of quick installation, enhanced feature set and advanced programming which allows installer to meet demands of the end user with flexibility in configuration. Equipped with configurable remote monitoring inputs, programmable relays, delay setting for alarm verification, software isolation of class B circuit and NAC outputs, mapping of NAC to specific class B circuits, password protections etc.

End users get clear visible indications, easy to operate functions to activate the control buttons, customizable class B circuit text via text inserts to meet building naming conventions. Reliable and trouble free system built as per latest safety standards of industry which ensures system is safe and protected. Internal memory lock feature to restrict changes to fire panel configuration by any intruder without key lock.

Product Description

• Display: 16 X 4 Char LCD Screen.
• Control Keys: Silence Buzzer, Silence/Resound Alarm, Reset, Evaluate, Accept delay.
• Indicators: Fault, NAC Fault, Earth Fault, Fire, Power, System Fault.

USER INTERFACE
16* 4 Char LCD display, Aesthetically designed front facia Fire, Fault, Configurable Relay Staged Delay configuration for alarm verification

Individual Class B Circuit Isolation Circuit wise NAC configuration Engineering Mute Configuration

Customizable text insert NAC Enable/Disable facility Battery Charging/Battery Internal Resistance Monitoring

Programmable input for remote reset/evacuate/alert/fire Monitored NAC and Class B Circuit for Open/Short/Faults
Aux output facility

Event Logging PC tool for advanced configuration needs/ Event exploring On board memory lock switch to prevent unauthorized panel configuration changes.

Lamp Test Facility One Man walk test facility delays to output, with timer to fire indication Detectors/MCPs in same circuit Upto 1000m cable connectivity per circuit, Typically 20 Detectors per Class B Circuit+ 5 MCP’s Latching/Non-Latching configuration for fault for easy debugging
Data/Time/Password configuration Earth Fault Monitoring Mechanical Key-lock
Separate configuration/user memories/system fault, sound/ resound feature like EN 54-4 standard Certified for Safety standard IEC 62368-1:2018 CE certificate

Mechanical Specifications
Dimensions (H X W X D)
360 X 422 X 122.8 mm (Front Facia),
360 X 380 X 92.3 mm (Back Box)
Weight
5.8 Kg Approx. (No Battery Fitted)
Construction
Powder coated Cold Rolled STEEL
1.2mm thick
Cable Entry
15 X 20mm Knockout
Operating Temperature
0 to 49°C
Relative Humidity
5% to 95% Non-Condensing

Standby Batteries
Minimum capacity 2 x 12 V 2.8Ah, Maximum capacity 2 x 12 V 7 Ah

Detection Circuits 2, 4, 6, 8 Class B Circuit, Max 2mA per Detect or Circuit

Approved Detectors Honeywell Morley Lite Series
Programmable Inputs Configurable (Alarm, Reset, Evacuate)
Programmable Input Extended closing contact

Trigger External Outputs
• 2 monitored outputs
• 0.5 Amps per circuit
Auxiliary Output:
• 18.5 to +28.5 Vdc, 0.5 Amp. (max)