WHAT WE’RE PRODUCTS
Sub Products
Product Details
FIRENETPLUS 2 LOOP ADDRESSABLE FIRE ALARM CONTROL PANEL
The FireNET Plus® 1127 series control panel is an analog addressable fire alarm panel with build options containing 1 or 2 SLC loops, a Digital Alarm Communicator/Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communication for peripheral devices. The RS-232 interface allows the convenience of programming via a PC.
The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module.
Product Description
• Analog design using Hochiki’s advanced DCPprotocol for fast communication
• Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
• Uses standard wire, no-shielded or twisted pair required on SLC loops
• Integrated digital alarm communicator (DACT) with Contact ID and SIA reporting formats
• Programmable sensitivity levels by device
• Alarm Verification feature
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 1 or 2 loop (option)
• RS-485 bus for panel network (option)
• Built-in RS-232 interface for programming via a PC
• 3 on board programmable Form C relays rated at 1 amp at 30VDC
• 2 auxiliary power outputs, each rated 360mA at 24 VDC
• Loop Explorer Windows® configuration utility
120V A C @ 2. 1 Amps 50/ 60hz or 220V A C @ 1. 1Am ps 50/ 60hz
24V DC @ 5. 25 Amps
4 Am p integrated
1. 25 Amps m ax.
14. 5” W x 19” H x 3. 5” D
20 lbs. (without batteries )
Red (optional gray)
A BS /s t eel enclosure
8 line x 40 character LCD (320 character total)
Dual RS 485 ports (64 panels max. )
500 net work wide s of t ware zones per system
1 or 2 (class A , “style 6 or 7” or class B, “style 4”)
127 sensors & modules, plus 127 analog sounder bases , 254 total
800 addresses + s ub-addresses max. per panel
(2) class B, 2.3 Amps (special application)
1. 6 Amps Regulated (continuous )
(3) Form C 1 Amp @ 30V DC
2 out puts , 360m A @ 24V DC each
RS 232 Contact ID and SIA