WHAT WE’RE PRODUCTS

Sub Products

Product Details

SS-4ZEC 4 ZONE FIRE ALARM CONTROL PANEL

Honeywell System Sensor Fire Alarm Control Panels have been developed to provide a simple and reliable solution to the demands of today’s fire detection solutions. The panels have been designed with both installer and end user’s requirements in mind suited for small to medium sized buildings like Commercial Buildings, Banking, Residential complexes, Retail Units/ Stores, Shops, Restaurants, Healthcare, Public Offices, Schools etc

For installers, Honeywell System Sensor panels offer an out of the box and on the wall solution. A combination of quick installation, an enhanced feature set and advanced programming allows installers to quickly and simply meet the demands of the user. Equipped with programmable relays, delay setting for alarm verification, software isolation of zone and NAC output, provide wide variety of choice for system installers to customize the need of an end user.

Engineered and built to the same high standard as all Honeywell Fire Control panels, this System Sensor panel forms an essential part of any fire detection requirement

Product Description

Display
16 X 2 Character LCD
Control Keys
Menu/OK, Silence, Navigation, and Reset buttons
Indicators – Fire, Power, Fault, NAC Fault, Earth Fault, Silence

Three Form-C relays (1 Fire, 1 Fault and 1 Fire/ Fault 2amps@30 VDC)
• 1 On-board NACs operating @ 0.5A/circuit
• Aux Output: 24VDC
• Sounder Output: 24VDC
• Feature Detection Circuits: 2 & 4 Zones (upto 20 Detectors + 5 MCPs)
• Zone wise Fire, Fault, Disable indication
• Panel keys: Silence Buzzer/Alarm; Reset; Navigation keys (Left, Right, Down, Menu/Ok)
• Lamp Test & Walk Test
• Standby power 24V DC (2 no’s of 12V, 7Ah Lead Acid Battery)
• Certification (CE, LVDE)
• Event Log- 1200 events
• Earth fault monitoring

Mechanical Specifications
Dimensions (H X W X D)
250 X 290X 100 mm
Weight 3.5kgs Approx (No battery fitted)
Construction Cold Rlled Steel with powder coated finish with door lock
Cable Entry 08 Number x 20.50mm knockout
Electrical Specifications
Operating Voltage 230VAC; 50 Hz Alarm Load (Sounder) 0.5Amp (max) NAC output 0.5Amp (max)
Operating Temperature 0ºC – 49ºC/32ºF – 120ºF
Relative Humidity 5% to 95% Non-Condensing
Standby Batteries Minimum capacity 2 x 12 V 2.8Ah Maximum capacity 2 x 12 V 7 Ah
Detection Circuits 2, 4, zone, Max 2mA per Detector Class B Circuit
External Outputs Sounder Outputs: 18.5 to +28.0 Vdc, 0.5 Amp. (max) Auxiliary Output: 18.5 to +28.0 Vdc, 0.5 Amp. (max)